SRS Stanford Research Systems 1 mHz to 102.4 kHzSR830 Lock-In Amplifier
Description of SRS Stanford Research Systems SR830 Lock-In Amplifier
The SR830 Lock-In Amplifier provides high performance at a reasonable cost. The instrument simultaneously displays the magnitude and phase of a signal, and it uses digital signal processing (DSP) to replace the demodulators, output filters, and amplifiers found in conventional lock-ins . The SR830 provides uncompromised performance with an operating range of 1 mHz to 102 kHz and 100 dB of drift-free dynamic reserve.
Key Features of SRS Stanford Research Systems SR830 Lock-In Amplifier
1 mHz to 102.4 kHz range
>100 dB dynamic reserve
5 ppm/°C stability
0.01 degree phase resolution
Time constants from 10 µs to 3 ks
(up to 24 dB/oct rolloff)
Auto-gain, -phase, -reserve & -offset
Reference source
GPIB and RS-232 interfaces
| Voltage inputs | Single-ended or differential |
| Sensitivity | 2 nV to 1 V |
| Current input | 106 or 108 V/A |
| Input impedance | |
| Voltage input | 10 MΩ + 25 pF, AC or DC coupled |
| Current input | 1 kΩ to virtual ground |
| Gain accuracy | ±1 % (±0.2 % typ.) |
| Noise | 6 nV/√Hz at 1 kHz 0.13 pA/√Hz at 1 kHz (106 V/A) 0.013 pA/√Hz at 100 Hz (108 V/A) |
| Line filters | 50/60 Hz and 100/120 Hz (Q=4) |
| CMRR | 100 dB at 10 kHz, decreasing by 6 dB/oct above 10 kHz |
| Dynamic reserve | >100 dB (without prefilters) |
| Stability | <5 ppm/°C |
SRS SR830 Input Channel
The SR830 Lock-In Amplifier has differential inputs with
SRS SR830 Extended Dynamic Reserve
The dynamic reserve of a lock-in amplifier at a given full-scale input voltage is the ratio (in dB) of the largest interfering signal to the full-scale input voltage. The largest interfering signal is defined as the amplitude of the largest signal at any frequency that can be applied to the input before the lock-in cannot measure a signal with its specified accuracy.
Conventional lock-in amplifiers use an analog demodulator to mix an input signal with a reference signal. Dynamic reserve is limited to about 60 dB, and these instruments suffer from poor stability, output drift, and excessive gain and phase error. Demodulation in the SR830
SRS SR830 Digital Filtering
The digital signal processor also handles the task of output filtering, allowing time constants from 10 µsec to 30,000 s, with a choice of 6, 12, 18 and 24 dB/oct rolloff. For low frequency measurements (below 200 Hz), synchronous filters can be engaged to notch out multiples of the reference frequency. Since the harmonics of the reference have been eliminated (notably 2F), effective output filtering can be achieved with much shorter time constants.
SRS SR830 Digital Phase Shifting
Analog phase shifting circuits have also been replaced with a DSP calculation. Phase is measured with 0.01° resolution, and the X and Y outputs are orthogonal to 0.001°.
SRS SR830 Frequency Synthesizer
The built-in direct digital synthesis (DDS) source generates a very low distortion (-80 dBc) reference signal. Single frequency sine waves can be generated from 1 mHz to 102 kHz with 4½ digits of resolution. Both frequency and amplitude can be set from the front panel or from a computer. When using an external reference, the synthesized source is phase locked to the reference signal.
SRS SR830 Auto Functions
Auto-functions allow parameters that are frequently adjusted to automatically be set by the instrument. Gain, phase, offset and dynamic reserve are each quickly optimized with a single key press. The offset and expand features are useful when examining small fluctuations in a measurement. The input signal is quickly nulled with the auto-offset function, and resolution is increased by expanding around the relative value by up to 100×. Harmonic detection is no longer limited to only the 2F component. Any harmonic (2F, 3F, ... nF) up to 102 kHz can now be measured without changing the reference frequency.
SRS SR830 Analog Inputs and Outputs
The SR830 has a user-defined output for measuring X, R,
SRS SR830 Internal Memory
The SR830 has two 16,000 point buffers to simultaneously record two measurements. Data is transferred from the buffers using the computer interfaces. A trigger input is also provided to externally synchronize data recording.
SRS SR830 Easy Operation
The SR830
1.Can you ship order to Canada or Australia?
Yes,we can .We send orders worldwide.
2. What delivery method do you use? and delivery time?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question?
You can contact us online or leave us messages below.
![]()
![]()
![]()
![]()